APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black

SKU
AP8853
£716.71 £597.26
In stock
NetShelter Metered Rack PDU, 0U, 1PH, 7.4kW 230V32A, 36 C13 and 6 C19 outlets, IEC 309 2P+E cord
More Information
AC outlets quantity 42 AC outlet(s)
SKU AP8853
EAN 0731304277019
Manufacturer APC
Availability Y
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Design
TypeSingle-phase
PDU typesMetered
MountingVertical
Product colourBlack
CertificationRoHS, REACH IEC 60950,VDE
Rack capacity0U
Ports & interfaces
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Power plugIEC309
Output connections36x IEC 320 C13 6x IEC 320 C19
Input connection typeIEC 309 32A 2P+E
Features
Cable length3 m
CertificationRoHS, REACH IEC 60950,VDE
Management features
MonitoringCurrent, Power, Voltage
Ergonomics
Cable length3 m
Power
Maximum power7680 W
Nominal output voltage230 V
Maximum total current draw per phase32 A
Maximum input current per phase32 A
Load capacity7680 VA
AC input frequency50 - 60 Hz
Certificates
CertificationRoHS, REACH IEC 60950,VDE
Operational conditions
Operating temperature (T-T)5 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Weight & dimensions
Weight6.93 kg
Width56 mm
Depth44 mm
Height1791 mm
Technical details
Total carbon footprint (kg of CO2e)28921.23
Logistics data
Total carbon footprint (kg of CO2e)28921.23

You may also be interested in

Compare Products
Product APC AP8853 power distribution unit (PDU) 42 AC outlet(s) 0U Black
Hot Product
APC AP8853 power distribution unit (PD...
£716.71 £597.26
APC AP8858 power distribution unit (PDU) 20 AC outlet(s) 0U Black APC AP8858 power distribution unit (PD...
£652.58 £543.82
APC AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U APC AP8858EU3 power distribution unit...
£707.96 £589.97
APC AP8881 power distribution unit (PDU) 42 AC outlet(s) 0U Black APC AP8881 power distribution unit (PD...
£1,051.52 £876.27
APC AP7822B power distribution unit (PDU) 16 AC outlet(s) 2U Black APC AP7822B power distribution unit (P...
£867.71 £723.09
APC AP7921B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black
Bestseller
APC AP7921B power distribution unit (P...
£773.58 £644.65
SKU
AP8853
AP8858
AP8858EU3
AP8881
AP7822B
AP7921B
Description
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (36) C13 & (6) C19, and the cable length is 3m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 220-240 volts via IEC C20 inlet (no cord provided) while power comes out at 100-230 volts through (18) C13 and (2) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 220-240 volts via IEC 309 2P + E plug with a 3m (10 ft) cord while power comes out at 230 volts through (18) C13 and (2) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh). This 3 phase PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity . This zeroU PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU via IEC 309 3P+N+PE plug with a 1.8m (16 ft) cord while power comes out at 230 volts through (36) C13 and (6) C19 locking outlets. It integrates with EcoStruxure IT, and daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
APC Metered Rack PDUs offer resilient power distribution and actively measure, display, and log amperage to support real-time monitoring and historical reporting. This PDU remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. The historical reporting enables users to optimize energy use and plan for capacity with confidence. This PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 200-230 volts via IEC 309 plug with a 3.6m (11 ft) cord while power comes out at 230 volts through (36) IEC 320 C13 and (6) IEC 320 C19 outlets. As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
This APC Switched Rack PDU power distribution unit has a wide range of standardized PDU features that increase network efficiency, manageability and functionality. The output and input connections are (8)C13. Network management capabilities allow you to configure and manage rack PDUs from remote locations. It has has a local current monitoring display that gives a visible warning in case of an overload. The remote individual outlet control provides real-time monitoring of connected loads. It has a multi-tier user access that enables you to restrict unauthorized use of outlets. This rack has a single input power source making it easy to install.
Short Description
NetShelter Metered Rack PDU, 0U, 1PH, 7.4kW 230V32A, 36 C13 and 6 C19 outlets, IEC 309 2P+E cord
NetShelter Metered Rack PDU, 0U, 1PH, 3.3kW 208V 16A or 3.7kW 230V 16A, 18 C13 and 2 C19 outlets, C20 inlet
NetShelter Metered Rack PDU, 0U, 1PH, 3.7kW 230V 16A, x18C13 and x2C19 outlets, IEC 309 cord
NetShelter Metered Rack PDU, 0U, 3PH, 11kW 230V 16A or 11kW 230V 16A, 36 C13 and 6 C19 outlets,IEC 309 3P+N+PE cord
NetShelter Metered Rack PDU, 2U, 1PH, 7.4kW 230V 32A, x12 C13 and x4 C19 outlets, IEC 309 cord
NetShelter Switched Rack PDU, 1U, 1PH, 3.7kW 230V 16A or 3.3kW 208V 16A, 8 C13 outlets, C20cord
Manufacturer
APC
APC
APC
APC
APC
APC